Rjs Inspector D4000 Laser (FIRMWARE version A.05 and E Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per Scanner Rjs Inspector D4000 Laser (FIRMWARE version A.05 and E. RJS Inspector D4000 Laser (FIRMWARE version A.05 and Earlier) User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 81
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Laser Inspector
Model L1000
TM
Operators Guide
Manual P/N 002-5568
Release Version: G
June 2011
RJS Technologies
701 Decatur Ave North, Suite 107
Minneapolis, MN 55427
(763) 746-8034 Phone
www.rjs1.com Website
Vedere la pagina 0
1 2 3 4 5 6 ... 80 81

Sommario

Pagina 1 - Model L1000

Laser Inspector Model L1000TM Operator’s Guide Manual P/N 002-5568 Release Version: G June 2011 RJS Technologies 701 Decatur Ave No

Pagina 2 - All right reserved

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 4 2.0 Warranty 2.1 General Warranty Warranty information: (763) 746

Pagina 3 - 4.0 THE LASER INSPECTOR 8

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 5 2.3 Service During The Warranty Period If your Laser Inspector sho

Pagina 4 - 5.2 SETUP 10

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 6 3.0 Introduction 3.1 Warnings  Do not point the laser gun in th

Pagina 5

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 7 3.2 Maintenance To ensure the best possible scanning conditions, k

Pagina 6

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 8 4.0 The Laser Inspector Figure 4-1 (Laser InspectorModel L1000)

Pagina 7 - 1.0 Preface

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 9 5.0 Main Menu Selections Note: Even though your Inspector may

Pagina 8

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 10 5.2 Setup Select Setup (from the Main Menu) to set various system

Pagina 9

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 11 The next selection is; UPC/EAN Rnd. Wt. OFF Note: Select ON to a

Pagina 10 - 2.0 Warranty

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 12 The next selection is: Decode I 2of 5 ANSI I 2 of 5 This allows

Pagina 11 - RJS, Minneapolis, MN

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 13 The next selection is : Database Storage XX kb XX kb Enter

Pagina 12 - 3.0 Introduction

Copyrights The copyrights in this manual are owned by RJS Technologies, Inc. All rights are reserved. Unauthorized repr

Pagina 13

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 14 The last menu setup selection is: Comparison Mode OFF Note: Com

Pagina 14 - 4.0 The Laser Inspector

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 15 5.3 Storage Storage is used to hold scan data for future print or

Pagina 15 - 5.0 Main Menu Selections

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 16 5.4 Storage and Database A special serial interface cable th

Pagina 16 - Operator’s Guide

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 17 The database function is defaulted to OFF and becomes active when

Pagina 17

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 18 Database XX Storage YY The cursor will be on the “D” in dat

Pagina 18

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 19 6.0 Scanning Symbols To scan a barcode simply pull the trigger a

Pagina 19

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 20 7.0 Pass/Fail Analysis Screen After a symbol is scanned the Pass/

Pagina 20

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 21 Table 1 (Code Identifiers Laser Inspector ) Displays Type LOGMA

Pagina 21 - 5.3 Storage

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 22 Table 2 (Identifier Descriptions for Pass/Fail Analysis Screens)

Pagina 22 - 5.4 Storage and Database

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 23 8.0 Data Analysis Screens After doing a scan, the Data Analysis S

Pagina 23

Operator’s Guide Models L1000 Laser InspectorTM 002-5568 iii RJS, Minneapolis, MN TABLE OF CONTENTS 1.0 PREFACE 1 1.1 PROPRIETARY STATEMENT 1

Pagina 24 - (Downloading Data)

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 24 For Code 128, the Mod check character is displayed as the symbolog

Pagina 25 - 6.0 Scanning Symbols

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 25 Press Select to bring up the next screen: Ratio: 2.9 D/bility .

Pagina 26 - (See 6.0 Scan

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 26 The closer the “A” is to the edge, the more likely a Warning or Re

Pagina 27

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 27 Press Select again to display the first technical Data Analysis sc

Pagina 28

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 28 8.1 Continuous and Multi-scan modes In the Continuous Mode, an add

Pagina 29 - 8.0 Data Analysis Screens

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 29 9.0 Connect to other Devices Connect to Computer Your Laser Inspe

Pagina 30

Appendix A Operator’s Guide RJS, Minneapolis, MN 002-5568 30 Appendix A (Code 128) Code 128 Code 128 can encode all the characters currentl

Pagina 31 - See Table 3

Operator’s Guide Appendix A 002-5568 RJS, Minneapolis, MN 31 Due to the flexibility and nature of Code 128, it is difficult to display “printa

Pagina 32 - Rejected

Appendix A Operator’s Guide RJS, Minneapolis, MN 002-5568 32 Example: * C L C 1 3 ? * A A B 3 R F C 2 4 ? * Re

Pagina 33

Operator’s Guide Appendix A 002-5568 RJS, Minneapolis, MN 33 Note: Only the first and last alphanumerics of each ASCII character are display

Pagina 34

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 iv 5.0 MAIN MENU SELECTIONS 9 5.1 SCAN 9 5.2 SETUP 10 5.3 STOR

Pagina 35 - Contact RJS for details:

Appendix A Operator’s Guide RJS, Minneapolis, MN 002-5568 34 Table A-2 (Code 128 — Subset B) SP ! " # $ % & '

Pagina 36 - Appendix A (Code 128)

Operator’s Guide Appendix A 002-5568 RJS, Minneapolis, MN 35 Table A-3 (Code 128 — Subset C) 00 01 02 03 04 05 06 07 08

Pagina 37 - Operator’s Guide Appendix A

Appendix A Operator’s Guide RJS, Minneapolis, MN 002-5568 36 Note: On the LCD Display the Inspector will show a Yen symbol “¥”instead of a backs

Pagina 38 - * C L C 1 3 ? *

Operator’s Guide Appendix B 002-5568 RJS, Minneapolis, MN 37 Appendix B (Code 93) Code 93 Code 93 encodes 43 data characters consisting of 0-9, A

Pagina 39 - Inspector

Appendix B Operator’s Guide RJS, Minneapolis, MN 002-5568 38 * is substituted for Stop/Start characters < is substituted for encircled

Pagina 40

Operator’s Guide Appendix B 002-5568 RJS, Minneapolis, MN 39 Table B-1 (Code 93 Character Set) ASCII CODE 93 ASCII CODE 93 ASCII CODE 93 ASC

Pagina 41

Appendix C Operator’s Guide RJS, Minneapolis, MN 002-5568 40 Appendix C (Battery Displays) Battery Displays If the “Low Battery” condition displ

Pagina 42 - Appendix A Operator’s Guide

Operator’s Guide Appendix D 002-5568 RJS, Minneapolis, MN 41 Appendix D (Magnifications) UPC/EAN Magnifications & Bar Width Deviations UPC a

Pagina 43 - Appendix B (Code 93)

Appendix E Operator’s Guide RJS, Minneapolis, MN 002-5568 42 Appendix E (Print Functions) Print Functions Scanned data may be printed if the Las

Pagina 44 - Appendix B Operator’s Guide

Appendix E Operator’s Guide 002-5568 RJS, Minneapolis, MN 43 Figure E-1 (Continuous scan) Laser Inspector L1000 Rev. X Cont. Scan Analysis ANS

Pagina 45

Operator’s Guide Models L1000 Laser InspectorTM 002-5568 v RJS, Minneapolis, MN TABLE A-2 (CODE 128 — SUBSET B) 34 TABLE A-2 (CODE 128 — SUB

Pagina 46 - Battery Displays

Appendix F Operator’s Guide RJS, Minneapolis, MN 002-5568 44 Appendix F (Symbology Analysis) Symbology Analysis Parameters Table F-1 shows error

Pagina 47 - Appendix D (Magnifications)

Operator’s Guide Appendix F 002-5568 RJS, Minneapolis, MN 45 Table F-2, (Parameters Checked for Each Symbology) Symbology Ratio ICG Data Cha

Pagina 48 - Appendix E (Print Functions)

Appendix F Operator’s Guide RJS, Minneapolis, MN 002-5568 46 NOTES: 1. X = X dimension 2. Tolerance is expressed as a fraction of the X dimensi

Pagina 49

Operator’s Guide Appendix G 002-5568 RJS, Minneapolis, MN 47 Appendix G (ANSI Decodability) ANSI Decodability Calculations There is a specified me

Pagina 50 - Appendix F Operator’s Guide

Appendix G Operator’s Guide RJS, Minneapolis, MN 002-5568 48

Pagina 51

Operator’s Guide Appendix H 002-5568 RJS, Minneapolis, MN 49 Appendix H (Scanning Technique) The RJS Inspector bar code verifier that is supplied

Pagina 52

Appendix H Operator’s Guide RJS, Minneapolis, MN 002-5568 50 Figure 1 – Scanning angle and distance

Pagina 53 - < .25 = F

Operator’s Guide Appendix I 002-5568 RJS, Minneapolis, MN 51 Appendix I (Quiet Zone Analysis) Quiet Zone Analysis The Laser Inspector trims d

Pagina 54 - Appendix G Operator’s Guide

Appendix I Operator’s Guide RJS, Minneapolis, MN 002-5568 52 Table I-2 (Acceptable Parameters for Symbols With Addendums) Symbology Leading Q

Pagina 55 - Operator’s Guide Appendix H

Operator’s Guide Appendix J 002-5568 RJS, Minneapolis, MN 53 Appendix J Downloading the Database See also 5.4 Storage and Database Database Se

Pagina 56 - Appendix H Operator’s Guide

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 vi APPENDIX G (ANSI DECODABILITY) 47 ANSI DECODABILITY CALCULATIONS

Pagina 57 - Operator’s Guide Appendix I

Appendix J Operator’s Guide RJS, Minneapolis, MN 002-5568 54 (You can have many records (like the record above), stacked in a file. The start cha

Pagina 58 - With Addendums)

Operator’s Guide Appendix J 002-5568 RJS, Minneapolis, MN 55 Step 5) Using the COPY command, download the sample data base: COPY DBSAMP

Pagina 59 - Appendix J

Appendix J Operator’s Guide RJS, Minneapolis, MN 002-5568 56 Data Base Record Does Not Exist (If the scanned symbol does not match the rec

Pagina 60 - Appendix J Operator’s Guide

Operator’s Guide Appendix J 002-5568 RJS, Minneapolis, MN 57 EAN-13 The EAN-13 database key must be made up of all 13 digits in the barcode (inclu

Pagina 61 - Operator’s Guide Appendix J

Appendix J Operator’s Guide RJS, Minneapolis, MN 002-5568 58 Code 93 The Code 93 database key must be made up of all the printable data characters

Pagina 62 - Key Field Descriptions

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 59 Appendix K Barcode Definitions (Some of these definitions may not be applicable to t

Pagina 63

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5568 60 Barcode A group of parallel bars and spaces constituting characters that are machin

Pagina 64

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 61 Bit The narrowest code element (bar of space) that may contain information. Characte

Pagina 65 - Appendix K

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5568 62 Decode Determining the information which has been encoded in a barcode symbol. Deco

Pagina 66 - Appendix K Operator’s Guide

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 63 Element A generic term used to refer to either a bar or space in a barcode symbol. E

Pagina 67

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 1 1.0 Preface 1.1 Proprietary Statement The RJS Model L1000 Laser I

Pagina 68

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5568 64 Fixed Beam Scanner A barcode reading device wherein coded items pass across a statio

Pagina 69

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 65 Infinite Pad Method The method for measuring reflectance in which the sample substrat

Pagina 70

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5568 66 Maximum Element Reflectance Nonuniformity (ERN max) The largest element reflectance

Pagina 71

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 67 MOD = ECmin/SC The greater the difference between minimum edge contrast and symbol c

Pagina 72

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5568 68 No-Read (Non-read, Non-scan) The absence of data at the scanner output after an atte

Pagina 73

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 69 Peak The graphical pattern on a scan reflectance profile which looks like an upside d

Pagina 74

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5568 70 Reference Decode Each symbology type specifies a specific decoding method to

Pagina 75

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 71 Scanner An electronic device that converts printed information into electrical signal

Pagina 76

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5568 72 Specular Reflection Reflection of light from a surface at an angle equal and oppos

Pagina 77

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 73 Symbol Grade The simple average of all the overall profile grades using the standard

Pagina 78

Model L1000 Laser InspectorTM Operator’s Guide RJS, Minneapolis, MN 002-5568 2 1.5 Documentation Updates RJS strives to provide the best possible

Pagina 79 - 0.0 = F

Appendix K Operator’s Guide RJS, Minneapolis, MN 002-5568 74 Truncation Decreasing the length of the bars in a barcode symbol below the normal sp

Pagina 80

Appendix K Operator’s Guide 002-5568 RJS, Minneapolis, MN 75 Z Dimension The achieved width of the narrow elements. Computation of Z is accomplis

Pagina 81

Operator’s Guide Model L1000 Laser InspectorTM 002-5568 RJS, Minneapolis, MN 3 Remove batteries when the unit will not be used for a pe

Commenti su questo manuale